Skip to content
HeaterGuides
Electric Fireplace

Five Fireplace Draft Stoppers That Will Transform Your Comfort

On this page 9 sections
  1. Compare Fireplace Draft Stoppers
  2. Best Fireplace Draft Stoppers
  3. Best Gas Fireplace Draft Stopper Choices
  4. How To Match The Stopper To Your Fireplace
  5. Which Material Seals Best In Real Homes
  6. Sizing And Installation Without Guesswork
  7. Gas Fireplace Draft Stopper Safety And Clearances
  8. What To Do Next If Your Fireplace Still Drafts
  9. More Questions, Answered
Bottom line
The best fireplace draft stopper for most readers is the large masonry plug, because it fits most brick fireplaces up to 38 x 16 inches and goes in below the damper with no mess. If you’re trying to stop a chimney from acting like an open window, that size range matters more than the brand name on the bag.
The essentials
Measure the firebox, damper, or flue opening before you buy; the fit decides everything.
Choose a plug or wool blocker for masonry fireplaces and a magnetic or film-style cover only if the surface matches the product.
Do not use any stopper with an active vented gas log set unless the product is approved for that exact setup.
Remove every draft stopper before lighting a fire. A chimney that can breathe for heating can also breathe for smoke, which is the point.
If your fireplace is unused, the best stopper is the one you’ll actually install and remove without a wrestling match.

Compare Fireplace Draft Stoppers

RankModelBest forTypeMax fitInstall methodPrice
1Brick fireplaces with rectangular dampers up to 38 x 16 inchesInflatable polyurethane plugUp to 38 x 16 inchesBelow the damper; telescoping pole supports pillowCheck price
2Unused wood-burning fireplaces with a rectangular flue up to 13 x 35 inches100% Herdwick wool plug13 x 35-inch flue openingPressure fit just above the fireboxCheck price
3Smooth-surface fireplaces where you want a cut-to-fit face coverClear plastic cover39 x 78 inchesCut to size and attach with loop-and-hook tapeCheck price
4
avvkfcmn 13 x 35 Felt PlugBest Adjustable Felt
Rectangular flues up to 13 x 35 inches that need a trim-to-fit plugFire-resistant felt plug13 x 35 inches or smallerInsert above the fireplace with telescopic metal poleCheck price
5
Flamorrow Magnetic Vent CoverBest For Magnetic Vents
Magnetic fireplace vents measuring up to 40 x 4 inchesFlexible rubber magnetic cover40 x 4 inchesAttach to a magnetic fireplace ventCheck price

A fireplace opening can leak a surprising amount of warm air, even with the damper closed, which is why the right stopper usually pays off before midwinter. The trick is picking the style that matches your fireplace: masonry plug, wool flue blocker, magnetic cover, or a surface cover for smooth finishes.

One checkable number helps here: a standard plug-style stopper tops out at a specific opening size, while surface covers need a flat, smooth face to stick. Measure the opening before you shop, or you’ll end up buying a very expensive reminder that fireplaces were designed by optimists.

Best Fireplace Draft Stoppers

#1Best Overall
Battic Door Large Masonry Plug

Battic Door Large Masonry Plug

Best for Brick fireplaces with rectangular dampers up to 38 x 16 inches
The large inflatable plug is the simplest fit for most brick or masonry fireplaces with a rectangular damper. It installs below the damper, and the telescoping pole supports the polyurethane pillow without adhesives or a messy project. Choose it when you want to reduce drafts, odors and heat loss without covering the fireplace opening.
Maximum fit Up to 38 x 16 inchesMaterial PolyurethaneInstall location Below the damperSupport Telescoping pole
Why it made the cut
Fits most brick fireplaces with rectangular dampers
Installs below the damper with no mess
Black pillow and pole are barely noticeable
Good to know
Limited to rectangular masonry fireplace openings
Won’t suit a fireplace without the required damper area
Skip it if Skip it if your fireplace opening is rough brick at the face or your flue needs a pressure-fit plug above the firebox.
#2Best Wool Seal
Flueblocker 13 x 35 Wool Plug

Flueblocker 13 x 35 Wool Plug

Best for Unused wood-burning fireplaces with a rectangular flue up to 13 x 35 inches
The Flueblocker uses dense 100% Herdwick wool and a pressure fit, so it works with or without an existing damper. Press it into the flue just above the firebox, then pull the handle to remove it when you need the opening again. Its rigid shape suits readers who want a dedicated flue plug rather than a cover over the fireplace face.
Maximum flue opening 13 x 35 inchesActual wool dimensions 14 x 36 inchesMaterial 100% Herdwick woolWeight 2.6 lbsInstall method Pressure fit above the firebox
Why it made the cut
Works with a broken, missing or functioning damper
Installs in seconds with no tools or adhesives
Pressure fit helps block drafts, odors, noise and debris
Good to know
Cannot be used with active vented gas log sets
Fits a narrower flue size than the large masonry plug
Skip it if Skip it if you have active vented gas logs or haven’t fully disabled or removed the gas log set.
#3Best Clear Cover
Air Jade Clear Fireplace Cover

Air Jade Clear Fireplace Cover

Best for Smooth-surface fireplaces where you want a cut-to-fit face cover
The clear plastic cover closes off the fireplace opening while leaving the firebox visible. You cut the 39 x 78-inch sheet to shape and attach it with the included loop-and-hook tape, so removal and storage are straightforward. It suits a smooth surface, but the maker says the kit cannot be applied to rough or brick surfaces.
Cover size 39 x 78 inchesMaterial Clear plasticAttachment Included loop-and-hook tapeIncluded 1 piece of plastic cover film, 1 set of loop-and-hook tape a
Why it made the cut
Clear material preserves the view into the fireplace
Can be cut to fit different sizes and shapes
Waterproof and cold resistant
Good to know
Cannot be applied to rough or brick surfaces
Must be used only after the open fire is extinguished
Attaches across the fireplace opening rather than inside the flue
Skip it if Skip it if the cover would attach directly to rough brick or if you want a plug hidden below the damper.
#4Best Adjustable Felt
avvkfcmn 13 x 35 Felt Plug

avvkfcmn 13 x 35 Felt Plug

Best for Rectangular flues up to 13 x 35 inches that need a trim-to-fit plug
The fire-resistant felt plug has sewn-in loops and can be trimmed for flues measuring 13 x 35 inches or smaller. A telescopic metal pole helps place it in the narrow part of the chimney above the fireplace, where it compresses to close gaps. Pick it when an adjustable felt design fits your flue better than a fixed-size wool plug.
Maximum flue fit 13 x 35 inchesOverall size 14 x 36 inchesMaterial Fire-resistant feltAdjustability Three sewn-in loops; can be trimmedPole Telescopic metal pole
Why it made the cut
Can be trimmed to fit smaller flues
Includes a telescopic metal pole
Fire-resistant felt compresses to help close gaps
Good to know
Cannot be used with an active vented gas log set
Requires the damper to be slightly larger than the flue for a secure seal
The listed fit is limited to rectangular flues up to 13 x 35 inches
Skip it if Skip it if you have active vented gas logs or cannot confirm the flue and damper measurements.
#5Best For Magnetic Vents
Flamorrow Magnetic Vent Cover

Flamorrow Magnetic Vent Cover

Best for Magnetic fireplace vents measuring up to 40 x 4 inches
The Flamorrow cover is made for a different opening: a magnetic fireplace vent, not a chimney flue. Its flexible rubber magnet attaches to a magnetic vent, and the material can be cut to fit. Choose the two-pack when cold air or debris enters through a magnetic vent and you can confirm the vent itself is magnetic.
Quantity 2 packMaximum cover size 40 x 4 inchesMaterial Flexible rubber magnetInstall method Attach to a magnetic ventAdjustability Can be cut to fit
Why it made the cut
Two covers are included
Flexible rubber magnet attaches without drilling
Can be cut to fit and stored after removal
Good to know
Works only on magnetic fireplace vents
Must be removed before lighting the fireplace
Covers vents up to 40 x 4 inches
Skip it if Skip it if your fireplace has a chimney flue opening rather than a magnetic vent.

Best Gas Fireplace Draft Stopper Choices

Best Gas Fireplace Draft Stopper Choices

For an unused gas fireplace, a fireplace plug draft stopper is usually the practical choice because it blocks the flue below the damper instead of relying on a cover stuck to the front. The Fireplace draft stopper large plug is the best overall fit for a masonry fireplace when the opening is within its stated 38 x 16-inch range.

A gas fireplace with an open flue can still pull heated room air up the chimney when nobody is using it. Remove the stopper completely before lighting the fireplace; leaving an inflatable plug, wool blocker, or other obstruction in the flue is unsafe. Direct-vent gas fireplaces are a different setup, and their sealed vent system shouldn’t be altered with a draft stopper.

Fireplace situationWhat to chooseBefore operation
Masonry fireplace with a suitable rectangular openingFireplace draft stopper large plugRemove it before lighting
Rectangular damper or flue openingA plug or wool blocker sized to the measured openingCheck that it sits below the damper or in the specified flue location
Smooth metal or glass fireplace faceMagnetic or clear surface coverRemove it before using the fireplace
Active vented gas log setNo stopper unless the product specifically allows it and the logs are disabled or removedDo not operate with a stopper installed
The fireplace’s venting arrangement matters more than the stopper’s label.
Surface covers have limits
The Air Jade Fireplace Cover and Flamorrow Fireplace Vent Cover Magnetic, 2 Pack Draft Block… are surface-style options. They need a smooth, non-brick surface or a suitable magnetic vent; magnets won’t seal rough masonry, and a cover over the wrong opening won’t solve a chimney draft.
Gas appliance check
Never install a stopper over an active gas vent or use one with gas logs burning. If the product instructions don’t clearly allow the setup, disable or remove the gas logs and ask a qualified fireplace technician before blocking the flue.
In short
Choose a plug for an unused masonry fireplace and match its size to the opening. A gas fireplace draft stopper must come out before lighting, and active vented gas logs need special written approval plus disabled or removed logs.
From HeaterGuides · our own guidePage 8 is the room-by-room draft hunt; page 9 lists 25 cheap fixes.Winter Heating Bill Cutter: the printable guide and its Excel calculatorWinter Heating Bill CutterSee what every heater in your home really costs, heat the rooms you use, and cut the waste in 30 days.Cost-per-hour tables for every heaterThermostat schedule and draft-proofing planRunning-cost and bill calculator (Excel)$14.99 $9.99Get it for $9.99See what's inside and watch the 2-minute video →14-page printable PDF + Excel calculator · instant download · 30-day refund

How To Match The Stopper To Your Fireplace

To choose the best fireplace draft stopper, match the stopper’s location and dimensions to your fireplace first; marketing terms like universal or airtight can’t rescue a cover that’s the wrong shape. A fireplace plug draft stopper belongs below the damper or in the specified flue, while surface covers seal the front or a vent.

StyleWhere it installsMeasure before buying
Masonry fireplace plugBelow the damper, inside the fireplace openingOpening width and height
Wool flue blockerIn the flue above the firebox, if its design calls for that locationFlue opening width and height
Magnetic vent coverOver a smooth magnetic fireplace ventVent width and height
Clear film coverOn a flat, clean fireplace faceFlat face width and height, plus the usable sealing area
Measure the actual sealing surface, not the outer mantel or trim.

A masonry plug is the sensible starting point for a traditional brick fireplace because it seals inside the opening and doesn’t depend on an adhesive face. The Flueblocker for 13 x 35-inch Chimney and the avvkfcmn Chimney Flue Plug for 13 x 35-inch Rectangular Chimne… are intended for a specific rectangular size, so their names are a clue, not permission to skip measuring.

Wool flue blockers suit a flue location where the product can sit securely above the firebox, but the opening must match the blocker and the damper arrangement must allow installation. Magnetic vent covers are quicker to remove and work well on smooth steel vents; they won’t hold to brick. Clear film covers need a flat, clean face with enough smooth area for the film to seal, so textured stone and uneven brick are poor candidates.

Bring These Measurements
Opening width and height at the point where a masonry plug will sit
Flue opening width and height for a wool blocker or rectangular flue plug
Vent width and height for a magnetic vent cover
Flat, usable face width and height for a clear film cover
A photo showing the damper, vent, brick, trim, and any obstruction
Measure twice
Take measurements at the narrowest sealing point, then compare them with the product’s stated range. A 13 x 35-inch flue plug may fit a rectangular opening of that size, but a smaller damper throat or projecting brick can still prevent it from seating properly.

If the fireplace is gas-fired and you want a different appliance rather than a stopper, first identify the vent design; a direct vent gas fireplace doesn’t use a chimney plug as a routine draft fix.

Which Material Seals Best In Real Homes

A fireplace draft stopper seals best when its material can follow the opening instead of simply covering it; that’s why polyurethane inflatable plugs and wool pressure-fit blockers usually handle real masonry flues better than flat covers. For fireplace cover insulation, the goal is to slow air movement through the chimney, not to create a decorative panel that happens to sit over the opening.

MaterialHow it sealsBest fit
Polyurethane inflatable plugInflates inside the flue and presses against the sidesIrregular or slightly uneven flues
Herdwick woolCompresses into gaps as you push it into placeMasonry flues with rough edges
Clear plastic filmSticks across the fireplace opening as a broad air barrierFlat, clean surrounds
FeltCompresses lightly against the openingSmall gaps and gentle pressure-fit jobs
Magnetic rubberUses a rubber sheet and magnets to cover the faceFlat openings with a compatible metal surface
The material matters, but the contact it makes with the fireplace matters more.

Polyurethane inflatable plugs are forgiving because air pressure pushes the plug outward around the flue walls. They can work around small irregularities that would leave a rigid panel with gaps. Herdwick wool works on the same basic pressure-fit idea: the fibers compress during installation and fill uneven spots, though you still need the right size and a firm fit.

Clear plastic film covers and magnetic rubber covers need a flatter, more predictable surface. Film depends on continuous contact around its perimeter, while a magnetic cover needs a clean surface and enough compatible metal for its magnets to hold. Felt plugs sit between those choices: they’re simple and compressible, but they generally have less ability to conform than an inflatable plug or a thick wool blocker.

Myth
A bigger fireplace draft stopper always seals better.
Fact
Oversizing can make a pressure-fit plug hard to install or leave it sitting across the opening instead of sealing inside the flue. A good stopper is large enough to maintain contact without forcing the material, folding it sharply, or damaging the fit.
Useful Side Benefits
A sealed flue can reduce chimney noise and limit the path for odors, insects, and loose debris. Those are worthwhile secondary benefits; fit and air sealing should decide the purchase. If the fireplace is used again, remove the stopper before lighting a fire or operating an appliance.

Sizing And Installation Without Guesswork

A fireplace plug draft stopper should fit the opening where you install it, and the answer to “what size fireplace draft stopper do I need” starts with a tape measure—not the fireplace’s advertised width. Measure the actual opening at the stopper’s location, because a plug below the damper may need a different size than a cover fitted just above the firebox.

Worked Example: Masonry Opening
Say the masonry opening below the damper measures 36 inches wide by 15 inches high. A large masonry plug rated for openings up to 38 x 16 inches is within that range, so it has room to seal without being forced into the brickwork. Measure the narrowest part of the opening; a wider measurement at the face won’t help if the throat is smaller.
Measured opening36 x 15 inches
Plug rangeUp to 38 x 16 inches
ResultSuitable by measured dimensions
Worked Example: Flue Opening
Now say the rectangular flue opening measures 13 x 35 inches at the point where the stopper will sit. A Flueblocker for 13 x 35 Chimney or the similarly sized avvkfcmn Chimney Flue Plug matches that measurement, but check the product’s actual fit instructions before buying. A flue measurement cannot be substituted for the firebox width.
Measured flue13 x 35 inches
Stopper size13 x 35 inches
Check nextInstallation location and fit instructio
1
Measure
Wait until the fireplace is fully cool. Record width and height at the exact installation point, then check for a damper plate, ledge, mortar joints or a tapered throat.
2
Compare
Match those measurements to the stopper’s listed opening range. Leave enough material to form a seal, but don’t cram a plug into a space smaller than its instructions allow.
3
Install
Place a plug below the damper or above the firebox as its instructions specify. A surface cover belongs over a smooth, reasonably flat surround; it cannot seal reliably against rough brick.
4
Test for leaks
Run a hand around the edge on a cold, unused fireplace and look for gaps or loose corners. Remove the stopper before using the fireplace.
Remove Before Fire
Every stopper comes out before lighting a fire or operating the appliance. Heat can damage an inflatable or fabric plug, and a cover can block the flue when smoke and combustion gases need a clear exit.

The Air Jade Fireplace Cover and Flamorrow magnetic cover are surface-style options, so inspect the surface before choosing them. Rough brick, uneven mortar and a projecting hearth edge can leave a path for air even when the cover looks neatly fitted.

Gas Fireplace Draft Stopper Safety And Clearances

A gas fireplace draft stopper is safe only when the fireplace is fully off and the stopper is removed before the next use. The key detail is the vent: an active gas fireplace needs its designed route for exhaust, so don’t plug or cover that route while the appliance can run.

Propane Fireplaces And Venting

Propane fireplaces follow the same rule as natural-gas models: never block the vent or flue while the fireplace is operating. Vented gas logs need an open, properly functioning vent path; vent-free models have different requirements, and local rules may restrict or prohibit them. Check the appliance manual and local code before using a stopper with any gas setup.

Disable The Fireplace First
Before fitting a stopper, turn the fireplace off and follow the manual’s shutdown instructions. If you can’t confirm the unit is disabled, don’t install the stopper. Never use one to cover a fireplace that might start from a wall switch, remote or thermostat.

A stopper can reduce drafts through an unused fireplace, but it can’t fix a stuck damper, damaged flue, loose masonry or a leaking chimney cap. If you smell gas or exhaust, see smoke enter the room, or find damage, stop using the fireplace and have a qualified fireplace technician inspect it. For a new vented gas fireplace, the vent type and installation clearances must match the appliance listing and local code.

In short
Use a stopper only in a fireplace that’s off and out of service, and remove it before relighting. If the draft continues or you’re unsure how the gas fireplace vents, get the appliance and chimney checked rather than sealing the opening tighter.

What To Do Next If Your Fireplace Still Drafts

In short
If a gas or propane fireplace is still in use, don’t install a draft stopper in its firebox or vent: the appliance needs the venting specified by its manual. For an unused fireplace, check the stopper fit first; if cold air still enters, look for a leaking damper or gaps around the surround.
1
Confirm the fireplace is out of service
A stopper is for a fireplace you will not operate while it’s installed. Never block the flue or vent of an active gas or propane fireplace; follow the appliance manual for venting and clearances. If you’re unsure whether the unit is still connected or usable, have a qualified fireplace professional check it.
2
Trace where the cold air enters
With the stopper fitted, check the edges of the fireplace surround and the damper area on a cold, windy day. Air around the surround suggests a gap in the facing; air coming through the flue may point to a damper that doesn’t close or seal properly. A larger stopper won’t fix either problem.
3
Choose a repair or a different fireplace
Ask a qualified chimney or fireplace professional to inspect a damaged damper, loose surround or persistent flue draft. If you want to replace a gas fireplace with an electric one, have the gas supply safely disconnected and capped as required, and check local permit and electrical requirements before removing the old unit. For options, compare indoor electric fireplaces; if you want to keep gas, see direct-vent gas fireplaces.

More Questions, Answered

What Is A Fireplace Draft Stopper?
A fireplace draft stopper is a removable barrier that closes an unused fireplace opening or flue path. Common types include inflatable plugs placed below the damper, pressure-fit wool blockers, and magnetic covers for compatible metal surfaces. Remove any stopper before using the fireplace.
How Does A Fireplace Draft Stopper Work?
The stopper reduces the open path between your room and the chimney, limiting cold air movement and heat loss. An inflatable plug presses against the flue walls, while a hearth cover seals the room-side opening. It won’t repair a damaged damper, missing liner or chimney masonry problem.
What Size Fireplace Draft Stopper Do I Need?
Measure the exact opening where the stopper will sit, including its width and height at the narrowest point. For the large masonry plug in this guide, the stated fit is up to 38 by 16 inches, but other designs use different dimensions. A stopper that is too small can shift or leak around its edges.
Can I Use A Fireplace Draft Stopper With Gas Logs?
Don’t install or leave a draft stopper in place while gas logs or another fuel-burning appliance is operating. Gas appliances need the venting and clearances specified by their manuals, and a blockage can create a carbon monoxide hazard. For an unused gas fireplace, have the appliance status and flue arrangement confirmed before blocking the opening.
Do Magnetic Fireplace Vent Covers Work On Brick?
A magnetic cover won’t stick directly to ordinary brick because brick isn’t magnetic. It can work when the fireplace has a steel surround or a suitable metal surface, provided the cover fits tightly and the appliance is not in use. Measure the metal area rather than assuming the masonry opening is the cover size.
Can I Make My Own Fireplace Draft Stopper?
You can make a temporary room-side blocker from a rigid panel with a compressible edge, but label it clearly so nobody lights the fireplace with it installed. Keep homemade materials away from heat, sparks and appliance controls, and don’t use one to block a flue serving an appliance. A listed removable plug is easier to size and less likely to be forgotten.

Joye Editor

HeaterGuides covers home heating, water heating and HVAC: how the equipment works, what it costs to run, and how to use it safely.

More in Electric Fireplace